 Human Inhibin A (INH-A) ELISA Kit
Catalog No. CSB-E08237h
(96T)
This immunoassay kit allows for the in vitro quantitative determination of human INH-A concentrations in serum, plasma a-n-d other biological fluids.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
廈門慧嘉生物長期經(jīng)營ELISA試劑盒及Santa/Abcam抗體、Prospec細(xì)胞因子、Sigma/Amresco/Qiagen、Axygen耗材等生物試劑產(chǎn)品。誠信經(jīng)營,價格實惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來詢!:   :  1048735792 或登陸http://www.biohj.com/download.aspx(向客服人員索取原版說明書)
 
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with goat-anti-rabbit antibody. Sta-n-dards or samples are then added to the appropriate microtiter plate wells with a Horseradish Peroxidase (HRP)-conjugated INH-A a-n-d antibody preparation specific for INH-A, a-n-d incubated. Then substrate solutions are added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution a-n-d the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of INH-A in the samples is then determined by comparing the O.D. of the samples to the sta-n-dard curve.
DETECTION RANGE
0.32 pg/ml-80 pg/ml. The sta-n-dard curve concentrations used for the ELISA’s were 80 pg/ml, 20 pg/ml, 5 pg/ml, 1.24 pg/ml, 0.32 pg/ml.
SPECIFICITY
This assay recognizes human INH-A. No significant cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of human INH-A is typically less than 0.2 pg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.
MATERIALS PROVIDED
Reagent Quantity
Assay plate 1 Sta-n-dard 5 x 0.5 ml HRP-Conjugate 1 x 6ml Antibody 1 x 6 ml
1 x15 ml
Wash Buffer
(20×concentrate) Substrate A 1 x 7 ml Substrate B 1 x 7 ml Stop Solution 1 x 7 ml

Standard
S1
S2
S3
S4
S5
Concentration(pg/ml)
0.32
1.24
5
20
80

STORAGE
1.    Unopened test kits should be stored at 2-8°C upon receipt a-n-d the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit. Refer to the package label for the expiration date.
2.    Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3.    A microtiter plate reader with a ba-n-dwidth of 10 nm or less a-n-d an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
REAGENT PREPARATION
1         Bring all reagents to room temperature before use.
2         Wash Buffer If crystals have formed in the concentrate, warm up to room temperature a-n-d mix gently until the crystals have compley dissolved. Dilute 15 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 300 ml of Wash Buffer.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, ha-n-d, face, a-n-d clothing protection when using this material.
OTHER SUPPLIES REQUIRED
1          Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
2          Pipettes a-n-d pipette tips.
3          Deionized or distilled water.
4          Squirt bottle, manifold dispenser, or automated microplate washer.
 
SAMPLE COLLECTION A-N-D STORAGE
? Serum Use a serum separator tube (SST) a-n-d allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 x g. Remove serum a-n-d assay immediay or aliquot a-n-d store samples at -20° C. Avoid repea ted freeze-thaw cycles.
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents a-n-d samples to room temperature before use. It is recommended that all samples, sta-n-dards, a-n-d controls be assayed in duplicate.
1         Set a Blank without any solution. Add 50µl of Sta-n-dard or Sample per well.
2         Add 50µl of HRP-Conjugate a-n-d 50µl of Antibody to each well. Not to Blank well!
3         Cover with the adhesive strip. Incubate for 1 hour at 37°C.
4         Aspirate each well a-n-d wash, repeating the process three times for a total of three washes. Wash by filling each well with Wash Buffer (200µl) using a squirt bottle, multi-channel pipette, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate a-n-d blot it against clean paper towels.
5         Add 50µl of Substrate A a-n-d 50µl of Substrate B to each well. Incubate for 15 minutes at 37°C. Keeping the plate away from drafts a-n-d other temperature fluctuations in the dark.
6         Add 50µl of Stop Solution to each well when the first four wells containing the highest concentration of sta-n-dards develop obvious blue color. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
7         Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS
Average the duplicate readings for each sta-n-dard, control, a-n-d sample a-n-d subtract the average zero sta-n-dard optical density. Create a sta-n-dard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a sta-n-dard curve by plotting the mean absorbance for each sta-n-dard on the y-axis against the concentration on the x-axis a-n-d draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the INH-A concentrations versus the log of the O.D. a-n-d the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the sta-n-dard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
1          The kit should not be used beyond the expiration date on the kit label.
2          Do not mix or substitute reagents with those from other lots or sources.
3          It is important that the Calibrator Diluent selected for the sta-n-dard curve be consistent with the samples being assayed.
4          If samples generate values higher than the highest sta-n-dard, dilute the samples with the appropriate Calibrator Diluent a-n-d repeat the assay.
5          Any variation in operator, pipetting technique, washing technique, incubation time or temperature, a-n-d kit age can cause variation in binding.
6          This assay is designed to eliminate interference by soluble receptors, binding proteins, a-n-d other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
 
TECHNICAL HINTS
1          Centrifuge vials before opening to collect contents.
2          When mixing or reconstituting protein solutions, always avoid foaming.
3          To avoid cross-contamination, change pipette tips between additions of each sta-n-dard level, between sample additions, a-n-d between reagent additions. Also, use separate reservoirs for each reagent.
4          When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, a-n-d/or rotating the plate 180 degrees between wash steps may improve assay precision.
5          To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
6          Substrate Solution should remain colorless until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless to gradations of blue.
7          Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
撥打電話
在線留言
99在线观看精品视频免费-国产极品一区二区三区四区| 亚洲av高清一区三区三区-久久人妻夜夜做天天爽| 美女把腿张开给帅哥桶-无码无套少妇18p在线直播| 黄片免费观看视频下载-国产丝袜诱惑在线视频| 久久特一级av黄色片-91社区视频免费观看| 欧美看片一区二区三区-人妻无卡精品视频在线| 日韩欧美国产综合久久-国产精品一起草在线观看| 在线视频成人一区二区-亚洲另类中文字幕在线| 亚洲另类自拍唯美另类-99国产精品兔免久久| 日本中文字幕啊啊啊啊-久久精品伊人久久精品伊人| 国产成人精品亚洲精品密奴-国产成人AV无码精品| 国产一区二区无套内射-国内精品久久久久久久齐pp| 久久高清超碰av热热久久-国产高清不卡免费视频| 精品一区二区三区av在线-欧美黑人巨大精品一区二区| 91精品国产无线乱码在线-999精品视频免费看| 国产一区二区三区噜噜-精品久久亚洲一区二区欧美| 日韩精品亚洲不卡一区二区-成人网在线视频精品一区二区三区| 久久特一级av黄色片-91社区视频免费观看| 少妇一区二区三区粉嫩av-国产精品区久久久久久久| 极品人妻av在线播放-久久精品视频一区二区三区| 国产黄片在现免费观看-色老板最新在线播放一区二区三区| 性都花花世界亚洲综合-日韩av一区二区三区| 成人免费黄色在线网站-日韩精品一区二区三区四区在线| 国产一级片久久免费看同-麻豆精品尤物一区二区青青| 久久久国产精品电影片-精品孕妇人妻一区二区三区| 99久热精品免费观看四虎-亚洲天堂精品视频在线| 亚洲综合av一区二区三区-高潮又爽又黄无遮挡激情视频| 麻豆久久国产精品亚洲-日本理论中文字幕在线视频| 国产美女裸露无遮挡双奶网站-国产精品色午夜视频免费看| 亚洲av综合av一区东京热-黄页免费视频网站在线观看| 交换朋友的妻子中文字幕-日本美女8x8x8x8| 精品亚洲卡一卡2卡三卡乱码-一区三区二插女人高潮在线观看| 精品少妇一区二区18-一区二区三区日韩在线播放| 亚洲视频一区二区三区免费-国产一级黄色大片在线| 久久网址一区二区精品视频-日产国产欧美视频一区精品| 国产av一区二区三区日韩接吻-av网址在线播放网站| 97人妻精品一区二区三区爱与-日韩精品亚洲专区在线观看| 亚洲午夜久久久精品影院-性感美女在线观看网站国产| 国产日韩电影一区二区三区-美女露双奶头无遮挡物| 亚洲av高清一区三区三区-久久人妻夜夜做天天爽| 欧美日韩国产综合四区-爆操极品尤物熟妇14p|