 Human Insulin-like Growth Factor 1(IGF-1)ELISA Kit
Catalog No. CSB-E04580h
(96 T)
This immunoassay kit allows for the in vitro quantitative determination of human IGF-1 concentrations in serum, plasma .
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
廈門慧嘉生物長(zhǎng)期經(jīng)營(yíng)ELISA試劑盒及抗體、細(xì)胞因子、生化試劑、耗材等生物試劑產(chǎn)品。誠(chéng)信經(jīng)營(yíng),價(jià)格實(shí)惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來詢!:   :  1048735792 或登陸http://www.biohj.com/download.aspx(下載原版說明書)
 
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with an antibody specific to IGF-1. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific for IGF-1 and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain IGF-1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of IGF-1 in the samples is then determined by comparing the O.D. of the samples to the standard curve.
DETECTION RANGE
7.8 ng/ml-500ng/ml. The standard curve concentrations used for the ELISA’s were 500 ng/ml, 250 ng/ml, 125 ng/ml, 62.5 ng/ml,
31.2 ng/ml, 15.6 ng/ml, 7.8 ng/ml.
SPECIFICITY
This assay recognizes human IGF-1. No significant
cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of human IGF-1 is typically less
than 2 ng/ml.
The sensitivity of this assay, or Lower Limit of Detection (LLD)
was defined as the lowest protein concentration that could be
differentiated from zero.
MATERIALS PROVIDED
Reagent Quantity
Assay plate 1 Standard 2 Sample Diluent 1 x 20 ml Biotin-antibody Diluent 1 x 10 ml HRP-avidin Diluent 1 x 10 ml Biotin-antibody 1 x 120μl HRP-avidin 1 x 120μl
1 x20 ml
Wash Buffer
(25×concentrate)
TMB Substrate 1 x 10 ml
Stop Solution 1 x 10 ml
STORAGE
1.    Unopened test kits should be stored at 2-8?C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date.
2.    Opened test plate should be stored at 2-8?C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3.    A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
REAGENT PREPARATION
Bring all reagents to room temperature before use.
1         Wash Buffer If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have compley dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer.
2         Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 500 ng/ml. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted standard serves as the high standard (500 ng/ml). The Sample Diluent serves as the zero standard (0 ng/ml). Prepare fresh for each assay. Use within 4 hours and discard after use.
3         Biotin-antibody Centrifuge the vial before opening. Dilute to the working concentration using Biotin-antibody Diluent(1:100), respectively.
4         HRP-avidin Centrifuge the vial before opening. Dilute to the working concentration using HRP-avidin Diluent(1:100), respectively.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
OTHER SUPPLIES REQUIRED
1          Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
2          Pipettes and pipette tips.
3          Deionized or distilled water.
4          Squirt bottle, manifold dispenser, or automated microplate washer.
5          An incubator which can provide stable incubation conditions up to 37°C±0.5°C.
 
SAMPLE COLLECTION AND STORAGE
1          Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum and assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
2          Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
 
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well.
1         Add 100μl of Standard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37°C.
2         Remove the liquid of each well, don’t wash.
3         Add 100μl of Biotin-antibody working solution to each well. Incubate for 1 hour at 37°C. Biotin-antibody working solution may appear cloudy. Warm up to room temperature and mix gently until solution appears uniform.
4         Aspirate each well and wash, repeating the process three times for a total of three washes. Wash: Fill each well with
 
Wash Buffer (200μl) and let it stand for 2 minutes, then
remove the liquid by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel. Complete removal of liquid at each step is essential to good performance.
 
1         Add 100μl of HRP-avidin working solution to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.
2         Repeat the aspiration and wash five times as step 4.
3         Add 90μl of TMB Substrate to each well. Incubate for 10-30 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark.
4         Add 50μl of Stop Solution to each well when the first four wells containing the highest concentration of standards develop obvious blue color. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
5         Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS
Using the professional soft "Curve Exert 1.3" to make a standard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the IGF-1 concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
1          The kit should not be used beyond the expiration date on the kit label.
2          Do not mix or substitute reagents with those from other lots or sources.
3          It is important that the Standard Diluent selected for the standard curve be consistent with the samples being assayed.
4          If samples generate values higher than the highest standard, dilute the samples with the appropriate Standard Diluent and repeat the assay.
5          Any variation in Standard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding.
6          This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
 
TECHNICAL HINTS
1          Centrifuge vials before opening to collect contents.
2          When mixing or reconstituting protein solutions, always avoid foaming.
3          To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
4          When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may improve assay precision.
5          To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
6          Substrate Solution should remain colorless or light blue until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless or light blue to gradations of blue.
7          Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.

會(huì)員登錄

×

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
撥打電話
在線留言
小12萝自慰喷水亚洲网站-chinese偷拍一区二区三区| 国产精品熟女视频一区二区-国产日韩精品欧美一区喷水| 欧美伦乱淫老妇女激情吧-亚洲女邻居精品二区久久| 亚洲国产精品日韩欧美-国产又粗又硬又大爽黄| 一区二区国产高清在线-日本高清无卡一区二区三区| 国产一区二区三区噜噜-精品久久亚洲一区二区欧美| 精品少妇一区二区18-一区二区三区日韩在线播放| 欧美日本亚一级二级三区久久精品-日韩欧美一区二区久久婷婷| 亚洲黑人欧美一区二区三区-亚洲一区二区三区免费视频播放| 成人av一区二区蜜桃-亚洲色图激情人妻欧美| 中文字幕人妻少妇第一页-隔壁的女孩在线看中文字幕| 97香蕉久久国产在线观看-麻豆黄色广告免费看片| 日韩中文字幕v亚洲中文字幕-日韩亚洲av免费在线观看| 三上悠亚免费观看在线-青青草原在线视频观看精品| 中文字幕亚洲综合久久最新-久久精品视频免费久久久| 国产欧美日韩中文字幕在线-国产伊人一区二区三区四区| 欧美mv日韩mv视频-熟妇人妻ⅴa精品中文| 蜜臀av日日欢夜夜爽一区-av在线免费永久播放| 黄片黄片在线免费观看-激情综合网激情五月俺也去| 天天干天天日天天射天天舔-精品香蕉视频官网在线观看| 国产成人精品亚洲精品密奴-国产成人AV无码精品| 色婷婷六月婷婷一区二区-91草草国产欧美在线观看| 男女做爰猛烈啪啪吃奶在线观看-人妻连裤丝袜中文字幕| 欧美字幕一区二区三区-好吊妞欧美一区二区在线观看| 成人免费黄色在线网站-日韩精品一区二区三区四区在线| 久久高清超碰av热热久久-国产高清不卡免费视频| 国产欧美日本一区二区-一区二区三区亚洲在线播放| av一区免费在线观看-中文字幕日韩国产精品视频| 国产亚洲欧美一区91-亚洲欧美一区二区在线| 国产精品久久久精品一区-99久久免费精品国产男女性高好| 国产在线不卡高清一区-日本一区二区三区四区无卡| 亚洲一区二区三在线观看-国产精品亚洲а∨天堂123| 中文不卡一区二区三区-老司机在线老司机在线一区| 欧美视频在线观看国产专区-亚洲91精品在线观看| 国产精品一区二区欧美视频-国产一区二区三区天码| 日本韩国亚洲欧美三级-日本东京不卡网一区二区三区| 少妇一区二区三区粉嫩av-国产精品区久久久久久久| 亚洲国产日韩精品四区-dy888午夜福利精品国产97| 一级特黄大片亚洲高清-国产精品视频伊人久久| 久久网址一区二区精品视频-日产国产欧美视频一区精品| 日本女优一卡二卡在线观看-欧美大胆a级视频秒播|