欧美……一区二区三区,欧美日韩亚洲另类视频,亚洲国产欧美日韩中字,日本一区二区三区dvd视频在线

廈門慧嘉生物科技有限公司
初級會員 | 第10年

18906011628

當(dāng)前位置:首頁   >>   資料下載   >>   CSB-E08678r大鼠腎上腺素(EPI)ELISA試劑盒說明書

CSB-E08678r大鼠腎上腺素(EPI)ELISA試劑盒說明書

時間:2011-12-8閱讀:163
分享:
  • 提供商

    廈門慧嘉生物科技有限公司
  • 資料大小

    101.1KB
  • 資料圖片

  • 下載次數(shù)

    40次
  • 資料類型

    WORD 文檔
  • 瀏覽次數(shù)

    163次
點擊免費下載該資料

 

 Rat Epinephrine/Adrenaline (EPI)ELISA Kit
Catalog No. CSB-E08678r
(96T)
This immunoassay kit allows for the in vitro quantitative determination of rat EPI concentrations in serum, plasma and other biological fluids.
Expiration date six months from the date of manufacture
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
廈門慧嘉生物長期經(jīng)營ELISA試劑盒及抗體、細胞因子、生化試劑、耗材等生物試劑產(chǎn)品。誠信經(jīng)營,價格實惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來詢!:   :  1048735792 或登陸http://www.biohj.com/download.aspx(下載原版說明書)
 
INTRODUCTION
Epinephrine (also known as adrenaline) is a hormone and neurotransmitter. When produced in the body it increases heart rate, contracts blood vessels, dilates air passages and participates in the fight-or-flight response of the sympathetic nervous system. It is a catecholamine, a monoamine produced only by the adrenal glands from the amino acids phenylalanine and tyrosine. The term adrenaline is derived from the Latin roots ad-and renes and literally means on the kidney, in reference to the adrenal gland's anatomic location on the kidney. The Greek roots epi-and nephros have similar meanings, and give rise to epinephrine. The term epinephrine is often shortened to epi in medical jargon. Adrenal extracts containing adrenaline were first obtained by Polish physiologist Napoleon Cybulski in 1895. These extracts, which he called "nadnerczyna", contained epinephrine and other catecholamines. Japanese chemist Jokichi Takamine and his assistant Keizo Uenaka independently discovered adrenaline in 1900.In 1901, Takamine successfully isolated and purified the hormone from the adrenal glands of sheep and oxen. Adrenaline was first synthesized in the laboratory by Friedrich Stolz and Henry Drysdale Dakin, independently, in 1904.
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with an goat-anti-rabbit antibody. Standards or samples are then added to the appropriate microtiter plate wells with a HRP-conjugated EPI and antibody preparation specific for EPI and incubated. Then substrate solutions are added to each well. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of EPI in the samples is then determined by comparing the O.D. of the samples to the standard curve.
DETECTION RANGE
16 pg/ml-4000 pg/ml. The standard curve concentrations used for the ELISA’s were 4000pg/ml, 1000 pg/ml, 250 pg/ml, 62pg/ml, 16 pg/ml.
SPECIFICITY
This assay recognizes recombinant and natural rat EPI. No significant cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of rat EPI is typically less than 10 pg/ml.
The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.
MATERIALS PROVIDED STORAGE

Reagent
Quantity
 
Assay plate
1
 
Standards (S1-S5)
5 x 0.5 ml
 
HRP-conjugate
1 x 6 ml
 
Antibody
1 x 6 ml
 
 
1 x 15 ml
 
Wash Buffer
 
 
 
(20×concentrate)
 
Substrate A
1 x 7 ml
 
Substrate B
1 x 7 ml
 
Stop Solution
1 x7 ml
 

Standard
Standard 1
Standard 2
Standard 3
Standard 4
Standard 5
Concentration (pg/ml)
16
62
250
1000
4000

 
1          Unopened test kits should be stored at 2-8?C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit. Refer to the package label for the expiration date.
2          Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3          A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
TECHNICAL HINTS
1          Bring all reagents and plate to room temperature for at least 30 minutes before use. Unused wells need store at 2-8and avoid sunlight.
2          Wash Buffer If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have compley dissolved. Dilute 15 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 300 ml of Wash Buffer.
3          To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
4          When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may improve assay precision.
5          To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary. Sealers can not be reused.
6          Substrate Solution should remain colorless until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless to gradations of blue.
7          Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye,
hand, face, and clothing protection when using this material.
OTHER SUPPLIES REQUIRED
1           Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
2           Pipettes and pipette tips.
3           Deionized or distilled water.
4           Squirt bottle, manifold dispenser, or automated microplate washer.
 
SAMPLE COLLECTION AND STORAGE
1           Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 x g. Remove serum and assay immediay or aliquot and store samples at -20°C. Avoid repeated freeze-thaw cycles.
2           Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot and store samples at -20°C. Avoid repeated freeze-thaw cycles.
 
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate.
 
1          Set a Blank well without any solution. Add 50μl of Standard or Sample per well. Standards need test in duplicate.
2          Add 50μl of HRP-conjugate to each well (not to Blank well), then add 50μl Antibody to each well. Mix well and then incubate for 1 hour at 37°C.
3          Fill each well with Wash Buffer (about 200μl), stay for 10 seconds and Spinning. Repeat the process for a total of three washes. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
4          Add 50μl of Substrate A and Substrate B to each well, mix well. Incubate for 15 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark.
5          Add 50μl of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
6          Determine the optical density of each well within 10 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS
Average the duplicate readings for each standard, Blank, and sample and subtract the optical density of Blank. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the EPI concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
1           The kit should not be used beyond the expiration date on the kit label.
2           Do not mix or substitute reagents with those from other lots or sources.
3           It is important that the Calibrator Diluent selected for the standard curve be consistent with the samples being assayed.
4           If samples generate values higher than the highest standard, dilute the samples with the appropriate Calibrator Diluent and repeat the assay.
5           Any variation in Standard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding.
6           This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Quantikine Immunoassay, the possibility of interference cannot be excluded.

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
撥打電話
在線留言
人妻丝袜中文字幕在线视频-亚洲成av人片一区二区三区| 国产av一区二区三区日韩接吻-av网址在线播放网站| 国产传媒中文字幕在线观看-午夜福利视频在线播放观看| 日本中文字幕永久在线人妻蜜臀-欧美一区二区的网站在线观看| 色婷婷六月婷婷一区二区-91草草国产欧美在线观看| 亚洲国产中文欧美一区二区三区-国产精品一区二区视频成人| 欧美精品国产白浆久久正在-国产精彩视频一区二区三区| 欧美日本亚一级二级三区久久精品-日韩欧美一区二区久久婷婷| 中文字幕精品一区二区日本99-青青国产成人久久91网| 国产老熟女激情小视频-成人一区二区人妻不卡视频| 免费午夜福利视频在线观看-亚洲成人日韩欧美伊人一区| 日本高清二区视频久二区-大香蕉在线视频大香蕉在线视频| 哦啊好大用力欧美视频-麻豆国产传媒片在线观看| 亚洲av高清一区三区三区-久久人妻夜夜做天天爽| hd在线观看一区二区-免费一区二区三区毛片在线| 日韩精品中文在线观看一区-亚洲bt欧美bt精品| 国产一区二区三区四区五区麻豆-欧美一级在线视频播放| 日本中文字幕永久在线人妻蜜臀-欧美一区二区的网站在线观看| 亚洲区欧美区在线视频-亚洲碰碰人人AV熟女天堂| 两性污污视频网站在线观看-亚洲欧美日韩激情一区| 日本中文字幕啊啊啊啊-久久精品伊人久久精品伊人| 青青操大香蕉在线播放-国产亚洲欧美精品在线观看| 精品少妇一区二区18-一区二区三区日韩在线播放| 国产一区二区三区噜噜-精品久久亚洲一区二区欧美| 97人妻精品一区二区三区爱与-日韩精品亚洲专区在线观看| 亚洲欧美一区二区中文-台湾中文综合网妹子网| 久久精品人妻一区二区三区极品-久久99热这里只有精品免费| 日本高清二区视频久二区-大香蕉在线视频大香蕉在线视频| 久久影视av一区二区-人妻激情乱偷一区二区三区| 亚洲欧美另类综合偷拍-婷婷社区综合在线观看| 一区二区国产高清在线-日本高清无卡一区二区三区| 国产欧美成人精品第一区-日本黄色精品一区二区| 91精品国产影片一区二区三区-欧美精品久久久精品一区二区| 亚洲综合久久综合激情-日韩欧美精品人妻二区少妇| 99热在线精品免费6-av一区二区在线观看| 国产精品电影在线一区-亚洲国产大片一区二区官网| 日本中文字幕永久在线人妻蜜臀-欧美一区二区的网站在线观看| 欧美黄色三级视频网站-国产九九热视频在线观看| 国产日韩电影一区二区三区-美女露双奶头无遮挡物| 欧美亚洲另类久久久精品-国产精品一区二区亚洲推荐| 俄罗斯胖老太太黄色特级片-国产精品黑丝美腿美臀|