 Rat complement factor H (CFH)ELISA Kit
Catalog No. CSB-E08932r
(96T)
?          This immunoassay kit allows for the in vitro quantitative determination of rat CFH concentrations in serum, plasma.
?          Expiration date six months from the date of manufacture
?          FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.
 
 
廈門慧嘉生物經(jīng)營ELISA試劑盒及抗體、細(xì)胞因子、生化試劑、耗材等生物試劑產(chǎn)品。誠信經(jīng)營,價格實惠,服務(wù)周到,質(zhì)量有保證。歡迎廣告老師來詢!:   : http://www.biohj.com/download.aspx說明書下載)
 
PRINCIPLE OF THE ASSAY
The microtiter plate provided in this kit has been pre-coated with an antibody specific to CFH. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for CFH and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB (3,3',5,5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain CFH, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ±2 nm. The concentration of CFH in the samples is then determined by comparing the O.D. of the samples to the standard curve.
DETECTION RANGE
31.2 pg/ml-2000 pg/ml. The standard curve concentrations used for the ELISA’s were 2000 pg/ml, 1000 pg/ml, 500 pg/ml, 250 pg/ml, 125 pg/ml,
62.5 pg/ml, 31.2 pg/ml.
SPECIFICITY
This assay recognizes rat CFH. No significant cross-reactivity or interference was observed.
SENSITIVITY
The minimum detectable dose of rat CFH is typically less than 7.8 pg/ml. The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest protein concentration that could be differentiated from zero.
MATERIALS PROVIDED
Reagent Quantity
Assay plate 1 Standard 2 Sample Diluent 2 x 20 ml Biotin-antibody Diluent 1 x 10 ml HRP-avidin Diluent 1 x 10 ml Biotin-antibody 1 x 120μl HRP-avidin 1 x 120μl
1 x 20 ml
Wash Buffer
(25×concentrate)
TMB Substrate 1 x 10 ml
Stop Solution 1 x 10 ml
STORAGE
1          Unopened test kits should be stored at 2-8?C upon receipt and the microtiter plate should be kept in a sealed bag. The test kit may be used throughout the expiration date of the kit, provided it is stored as prescribed above. Refer to the package label for the expiration date.
2          Opened test plate should be stored at 2-8?C in the aluminum foil bag with desiccants to minimize exposure to damp air. The kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
3          A microtiter plate reader with a bandwidth of 10 nm or less and an optical density range of 0-3 OD or greater at 450nm wavelength is acceptable for use in absorbance measurement.
 
REAGENT PREPARATION
Bring all reagents to room temperature before use.
1          Wash Buffer If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have compley dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to prepare 500 ml of Wash Buffer.
2          Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 ml of Sample Diluent. This reconstitution produces a stock solution of 2000 pg/ml. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted standard serves as the high standard (2000 pg/ml). The Sample Diluent serves as the zero standard (0 pg/ml). Prepare fresh for each assay. Use within 4 hours and discard after use.
3          Biotin-antibody Centrifuge the vial before opening. Dilute to the working concentration using Biotin-antibody Diluent(1:100), respectively.
4          HRP-avidin Centrifuge the vial before opening. Dilute to the working concentration using HRP-avidin Diluent(1:100), respectively.
 
Precaution: The Stop Solution provided with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
OTHER SUPPLIES REQUIRED
?          Microplate reader capable of measuring absorbance at 450 nm, with the correction wavelength set at 540 nm or 570 nm.
?          Pipettes and pipette tips.
?          Deionized or distilled water.
?          Squirt bottle, manifold dispenser, or automated microplate washer.
?          An incubator which can provide stable incubation conditions up to 37°C±0.5°C.
 
SAMPLE COLLECTION AND STORAGE
?          Serum Use a serum separator tube (SST) and allow samples to clot for 30 minutes before centrifugation for 15 minutes at 1000 g. Remove serum and assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
?          Plasma Collect plasma using citrate, EDTA, or heparin as an anticoagulant. Centrifuge for 15 minutes at 1000 g within 30 minutes of collection. Assay immediay or aliquot and store samples at -20°C. Centrifuge the sample again after thawing before the assay. Avoid repeated freeze-thaw cycles.
 
Note: Grossly hemolyzed samples are not suitable for use in this assay.
ASSAY PROCEDURE
Bring all reagents and samples to room temperature before use. It is recommended that all samples, standards, and controls be assayed in duplicate. All the reagents should be added directly to the liquid level in the well. The pipette should avoid contacting the inner wall of the well.
1          Recommend to dilute the serum or plasma samples with Sample Diluent(1:1000) before test. The suggested 1000-fold dilution can be achieved by adding 5μl sample to 95μl of Sample Diluent. Complete the 1000-fold dilution by adding 5μl of this solution to 245μl of Sample Diluent. The recommended dilution factor is for reference only. The optimal dilution factor should be determined by users according to their particular experiments.
2          Add 100μl of Standard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37°C.
3          Remove the liquid of each well, don’t wash.
4          Add 100μl of Biotin-antibody working solution to each well. Incubate for 1 hour at 37°C. Biotin-antibody working solution may appear cloudy. Warm up to room temperature and mix gently until solution appears uniform.
5          Aspirate each well and wash, repeating the process three times for a total of three washes. Wash: Fill each well with Wash Buffer (200μl) and let it stand for 2 minutes, then remove the liquid by flicking the plate over a sink. The remaining drops are removed by patting the plate on a paper towel. Complete removal of liquid at each step is essential to good performance.
6          Add 100μl of HRP-avidin working solution to each well. Cover the microtiter plate with a new adhesive strip. Incubate for 1 hour at 37°C.
7          Repeat the aspiration and wash five times as step 5.
8          Add 90μl of TMB Substrate to each well. Incubate for 10-30 minutes at 37°C. Keeping the plate away from drafts and other temperature fluctuations in the dark.
9          Add 50μl of Stop Solution to each well when the first four wells containing the highest concentration of standards develop obvious blue color. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
10      Determine the optical density of each well within 30 minutes, using a microplate reader set to 450 nm.
 
CALCULATION OF RESULTS
Using the professional soft "Curve Exert 1.3" to make a standard curve is recommended, which can be downloaded from our web.
Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the x-axis against the concentration on the y-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the CFH concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.
LIMITATIONS OF THE PROCEDURE
?          The kit should not be used beyond the expiration date on the kit label.
?          Do not mix or substitute reagents with those from other lots or sources.
?          It is important that the Standard Diluent selected for the standard curve be consistent with the samples being assayed.
?          If samples generate values higher than the highest standard, dilute the samples with the appropriate Standard Diluent and repeat the assay.
?          Any variation in Standard Diluent, operator, pipetting technique, washing technique, incubation time or temperature, and kit age can cause variation in binding.
?          This assay is designed to eliminate interference by soluble receptors, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
 
TECHNICAL HINTS
?          Centrifuge vials before opening to collect contents.
?          When mixing or reconstituting protein solutions, always avoid foaming.
?          To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
?          When using an automated plate washer, adding a 30 second soak period following the addition of wash buffer, and/or rotating the plate 180 degrees between wash steps may improve assay precision.
?          To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
?          Substrate Solution should remain colorless or light blue until added to the plate. Keep Substrate Solution protected from light. Substrate Solution should change from colorless or light blue to gradations of blue.
?          Stop Solution should be added to the plate in the same order as the Substrate Solution. The color developed in the wells will turn from blue to yellow upon addition of the Stop Solution. Wells that are green in color indicate that the Stop Solution has not mixed thoroughly with the Substrate Solution.

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
撥打電話
在線留言
人妻互换精品一区二区-夜夜爽一区二区三区视频| 日韩综合精品一区二区-丝袜美腿熟女人妻经典三级| 五月婷婷六月在线观看视频-亚洲黑寡妇黄色一级片| 一区二区国产高清在线-日本高清无卡一区二区三区| 激情字幕久久久字幕中文-一区二区三区免费黄片| 亚洲av成人一区国产精品网-国产偷_久久一级精品a免费| 日本亚洲精品中字幕日产2020-很黄很黄的裸交视频网站| 黑丝av少妇精品久久久久久久-中文字幕久久久人妻无码| 欧美精品国产系列一二三国产真人-在线观看国产午夜视频| 欧美日韩成人在线观看-久久五月婷婷免费视频| 天天日天天干天天综合-99久久综合狠狠综合久久| 日韩高清在线观看一区二区-美产av在线免费观看| 国产精品中出久久久蜜臀-久久久中国精品视频久久久| 中文字幕日韩精品不卡在线一区-国产tv日韩在线观看视频| 日韩二级视频在线观看-美女扒开奶罩露出奶子的视频网站| 人妻互换精品一区二区-夜夜爽一区二区三区视频| 婷婷综合在线视频观看-亚洲一区二区三区香蕉| 熟女熟妇伦51788-国产av在线播放一区二区三区| 精品亚洲卡一卡2卡三卡乱码-一区三区二插女人高潮在线观看| 黄片一区二区三区在线看-偷拍一区二区在线观看| 精品少妇一区二区18-一区二区三区日韩在线播放| 99在线观看精品视频免费-国产极品一区二区三区四区| 男人的天堂久久精品激情-最新亚洲精品a国产播放| 国产精品久久久精品一区-99久久免费精品国产男女性高好| 亚洲精品激情一区二区-久久成人国产欧美精品一区二区| 99在线免费观看视频-丰满人妻一区二区三区视频53| 中文字幕人妻少妇第一页-隔壁的女孩在线看中文字幕| 青青草原免费国产在线视频-精品人妻乱码一区二区三区四区| 男女做爰猛烈啪啪吃奶在线观看-人妻连裤丝袜中文字幕| 亚洲另类自拍唯美另类-99国产精品兔免久久| 亚洲欧美精品在线一区-99热国产在线手机精品99| 亚洲一区二区三在线观看-国产精品亚洲а∨天堂123| 国产免费高清av在线播放-成年人在线播放中文字幕| 一区二区三区国产高清mm-美女张开腿让帅哥桶爽| 蜜臀av日日欢夜夜爽一区-av在线免费永久播放| 99久热精品免费观看四虎-亚洲天堂精品视频在线| 91麻豆免费在线视频-欧美中文天堂在线观看| 欧美精品啪啪人妻一区二区-嫩草人妻舔舔羞羞一区二区三区| 狠狠狠狠爱精品一二三四区-l舌熟女av国产精品| 精品国产综合一区二区三区-蜜臀一区二区三区刺激视频| 性色国产成人久久久精品二区三区-偷窥中国美女洗澡视频|